• Nuclear Medicine • Radiation Oncology • Emergency Preparedness |
• PET Imaging • Nuclear Cardiology • Medical Physics |
| Home | Products | JRT Calibrations | Refurbished Equipment | Contact JRT |
FH- 40G Series Portable Dose Rate Survey Meters |
The FH-40 G is rugged, lightweight, fits snugly in the palm of the hand and is easy to operate with large keys that enable users wearing gloves. Internal diagnostics ensure proper functioning of the detector(s) and the electronics. If the battery voltage falls below a pre-defined value, an icon on the display flashes giving the user 20 hours of remaining use before replacing the batteries. Alarm values are established for dose rate and integrated dose. When an alarm value is exceeded, an audible alarm is emitted. In parallel to the measured value display, an audible speaker can be activated to signal detector pulses. The FH-40 G models are designed to record up to 256 data points containing measurement number, date, time and dose rate at the internal detector and external detector, status, and barcode information. The stored values can be read All settings can be accessed and the data analysis can be done, using an optional Windows™-based PC software. With the exception of the display instrument FH-40 G-X,
all FH-40 G versions incorporate an energy-filtered proportional
detector - no external probe or cable are required for
gamma dose rate measurements. The internal proportional
detector is always operational while an external detector is
connected. The external probes utilized with either model All FH-40 G versions and external probes containing the “-10” suffix are designed to meet the energy response
behavior of the new SI-units ambient dose equivalent Measured values are shown on a clear, backlit LCD display. Measure-ments are digital with a vertical 3 decade logarithmic bargraph. An intelligent rate meter algorithm (ADF mode) detects and
indicates small changes in dose rate, sup-pressing random
noise. Additional information includes alarm setting(s), A wide selection of External Detectors can be connected to FH-40 G with cable. Both values, from the external probe and the internal dose rate detector are simultaneously measured. For example: Each detector is automatically identified by the FH-40 G and the correct parameters are set. For both values separate alarms can be set. All external detectors are connected via a detector cable, with the exception of the Teleprobe FH-40 TG. All external detectors of the FH-40 G series are compatible with the FHT 6020 Display. Cable length may be up to 50 meters.
|
|